Skip to content
HTD Electronics Warehouse Open
Order in --Order now ships Today from Miami

Inverters, Battery Chargers and DC-DC Converters for Off-Grid Solar

MEAN WELL true sine wave inverters, battery chargers and DC-DC converters for the battery side of off-grid cabins, RVs and backup systems. Note: our MEAN WELL catalog does not include MPPT solar charge controllers, so pair these with the charge controller of your choice.

  • 12V · 24V · 48VBattery bank voltages for inverters and DC-DC converters
  • True sine waveInverters for electronics, motors and chargers
  • No MPPTCharge controllers are not part of this catalog
Overview

How an off-grid / backup system fits together

Solar panels charge the battery through a charge controller. The battery then feeds an inverter for 120VAC loads and DC-DC converters for 12V or 24V loads. A battery charger tops the bank up from the grid or a generator.

Solar panel → charge controller (MPPT/PWM, not in our catalog) → battery
Battery → inverter (120VAC loads) · DC-DC converter (12V/24V loads)
Grid or generator → battery charger → battery
Inverter

DC to 120VAC

True sine wave inverters (TS, NTS, NTU, TN) run AC loads from a 12V, 24V or 48V battery.

DC/AC inverters →

Charger

Grid or generator to battery

NPB, PB, ENC and DBR chargers with lead-acid and lithium charge curves.

Battery chargers →

DC-DC

Battery to DC loads

SD, RSD, DDR and DDRH convert the battery voltage to the 12V or 24V your loads need.

DC/DC converters →

DC/AC

Pure sine wave inverters: TS and TN series

True sine wave output for electronics, pumps, compressors and chargers. In TS and TN model numbers the digit after the wattage gives the AC output (1 = 100–120VAC, 2 = 200–240VAC) and the last two digits the battery voltage (12, 24 or 48 V). Check the datasheet for surge power and outlet type.

Show all 133 models (125 more)

See all true sine wave inverters →

Pure sine wave inverters: NTS, NTU, NTN and ISI

The NTS-1700-148US runs from a 48V battery (40–66 V input) and delivers 1700 W continuous with 3000 W surge (30 cycles) per its datasheet. NTU models add a UPS (transfer) function, and NTN and ISI models cover other power levels and battery voltages; check each datasheet.

Show all 100 models (92 more)

See all true sine wave inverters →

Modified sine wave inverters (A301, A302)

A lower-cost option for simple resistive loads. For electronics, motors and chargers use a pure sine wave model above.

Show all 12 models (4 more)

View all modified sine wave models →

Charging

Battery chargers for 12V, 24V and 48V battery banks

The NPB series datasheet lists a 2-stage charging curve for Li-ion batteries (lithium iron and lithium manganese) and a 3-stage curve for lead-acid (flooded, gel and AGM), selectable by DIP switch. Set the curve to match your battery and BMS.

Also listed: NPP, PB, RPB, RCB, DBR, DBU, NCP, ENC, ENP, ESC, ESP, PA and HEP charger models. Charging curves and battery types differ by series; check the datasheet.

NPB-360-24TB
NPB-360-24TB
360 W· 28.8 V· 12 A
$123.78
Shop now
DBR-3200-24
DBR-3200-24
3200 W· 24 V· 110 A
Request a quote
DBR-3200-48
DBR-3200-48
3200 W· 48 V· 55 A
Request a quote
DBU-3200-24
DBU-3200-24
3200 W· 24 V· 110 A
Request a quote
DBU-3200-48
DBU-3200-48
3200 W· 48 V· 55 A
Request a quote
ENC-120-12
ENC-120-12
120 W· 14.4 V· 8 A
Request a quote
ENC-120-24
ENC-120-24
120 W· 28.8 V· 4 A
Request a quote
ENC-180-12
ENC-180-12
180 W· 14.4 V· 12 A
Request a quote
Show all 89 models (81 more)

See all battery chargers →

DC/DC

DC-DC converters for 12/24/48 V loads

Run DC loads straight from the battery without an inverter. DDR-240C-24 takes a 48V bank (33.6–67.2 V input) down to 24V, DDR-120A-24 steps a 12V bank (9–18 V input) up to 24V, and SD-350B-24 gives an isolated, regulated 24V from a 24V bank (20–36 VDC input). DDRH and RSDH are designed for PV / renewable energy systems.

DDR-240C-24
DDR-240C-24
240 W· 24 V· 10 A
$167.58
Shop now
DDR-120A-24
DDR-120A-24
100.8 W· 24 V· 4.2 A
$91.47
Shop now
SD-350B-24
SD-350B-24
350.4 W· 24 V· 14.6 A
$135.62
Shop now

DDRH series for PV systems →

Sizing

Sizing an inverter: continuous vs surge watts

Add up the running watts of everything that can be on at the same time and divide by 0.8. Then check the start-up surge of motors and compressors (often several times their running watts) against the inverter surge rating.

Battery current is roughly inverter watts ÷ battery voltage ÷ efficiency, so a 1700 W load on a 48V bank draws about 37.5 A, while the same load on 12V would need over 140 A.

Continuous rating ≥ running watts ÷ 0.8
Surge rating ≥ largest motor start-up watts + other running loads
Battery current (A) ≈ watts ÷ battery voltage ÷ efficiency
Quick inverter / DC load calculator
Total load–
Current–
Choose a supply rated at least–

Enter battery current or total watts. Estimate only; check surge and efficiency in the MEAN WELL datasheet.

Hybrid

Bidirectional / hybrid options (BIC, NTN)

For systems that both charge and discharge a battery through one unit, the BIC series is a bidirectional AC⇄DC power supply, and the NTN-5K series is a 5 kW true sine wave inverter with AC charger and UPS function (per its datasheet). Both are quoted per project: tell us the battery voltage, power and grid conditions.

BIC series →

Bidirectional power supplies (BIC-2200)

BIC-2200 bidirectional AC-DC / DC-AC power supplies in 12V, 24V and 48V, with and without CANBus. Check the datasheet for the operating modes your system needs.

BIC-2200-12
BIC-2200-12
2200 W· 12 V· 180 A
Request a quote
BIC-2200-12CAN
BIC-2200-12CAN
2200 W· 12 V· 180 A
Request a quote
BIC-2200-24
BIC-2200-24
2200 W· 24 V· 90 A
Request a quote
BIC-2200-24CAN
BIC-2200-24CAN
2200 W· 24 V· 90 A
Request a quote
BIC-2200-48
BIC-2200-48
2200 W· 48 V· 45 A
Request a quote
BIC-2200-48CAN
BIC-2200-48CAN
2200 W· 48 V· 45 A
Request a quote
BIC-2200-96
BIC-2200-96
2200 W· 96 V· 22.5 A
Request a quote
BIC-2200-96CAN
BIC-2200-96CAN
2200 W· 96 V· 22.5 A
Request a quote

View all BIC models →

Off-grid inverter and charger FAQs

What size inverter do I need for an off-grid cabin or RV?

List the loads that can run at the same time, add their running watts and divide by 0.8 for the continuous rating. Then make sure the surge rating covers the start-up of the largest motor or compressor. Above about 1–2 kW, a 24V or 48V battery bank keeps the current manageable.

Pure sine wave vs modified sine wave: which do I need?

Pure (true) sine wave inverters work with electronics, motors, compressors and chargers. Modified sine wave is cheaper but can cause noise, heat or malfunction in some motors and electronics. For mixed loads, choose true sine wave.

Can I charge a LiFePO4 battery with a MEAN WELL charger?

Yes, with a model whose datasheet lists a lithium curve. The NPB series offers a 2-stage curve for Li-ion (lithium iron and lithium manganese) batteries; set it to match the battery and BMS limits.

12V, 24V or 48V battery bank: which is better?

Higher voltage means lower current for the same power, so thinner cables and lower losses. 12V suits small RV and cabin systems, 24V mid-size systems, and 48V systems of a few kilowatts.

Can the inverter be connected directly to solar panels?

No. These inverters run from a battery. Solar panels must charge the battery through a charge controller, which is not part of our MEAN WELL catalog.

What is a UPS / transfer function on an inverter (NTU)?

The NTU series is a true sine wave inverter with UPS function: it passes utility AC to the load and switches to battery power when the utility fails. Ask us for the transfer details of the model you need.

How do I power 12V devices from a 48V battery?

Use a DC-DC converter with a 48V-range input and 12V output from the SD, RSD or DDR series, sized at the 12V load ÷ 0.8. This avoids running small DC loads through the inverter.

Need help choosing?

Send your battery voltage, the loads you want to run and the backup time to sales@htdelectronics.com, or request a quote.