MEAN WELL power supplies for CCTV cameras, access control and alarm panels: UPS-function supplies that charge a backup battery and keep cameras recording through a power cut, DIN rail security models and 12V adapters for single cameras.
A UPS-function supply has two jobs: it powers the cameras or panel, and it charges a sealed lead-acid battery. When AC fails, the battery takes over the load without a gap. For 12V systems the output sits at about 13.8V, the float voltage of a 12V lead-acid battery (for example AD-55 and SCP-50 datasheets).
The A-versions are the 12V (13.8V) models. They are available by quote; tell us the camera load and battery size.
Single output with battery charger (UPS function), with alarm signals for AC OK and battery low on the PSC-60.
Single output with battery charger (UPS function): 13.8V on the AD-55A, with AC fail and battery low signals.
Single output supply with 13.8V output on the 12V model and AC OK / AC fail signal (SCP-50 datasheet).
These supplies power the cameras or panel and charge a backup battery in one unit; their specs list a battery charger or UPS function. Output voltage, battery type and alarm signals vary by model; check the datasheet.
View all PSC models →View all SCP, AD, ADD and LAD models →Security & specific power supplies →
B-versions provide 24V-class output for 24V cameras, PTZ heaters and larger access control systems with a 24V battery bank (two 12V batteries in series). Available by quote.
For security cabinets with DIN rail. The DRS-240-24 combines a 24V supply, battery charger and DC UPS function with AC fail and battery low signals. DRC models add a UPS function, and DR-UPS40 and DUPS modules add battery backup to an existing 24V supply.
Battery capacity (Ah) ≈ load current (A) × backup time (h) ÷ 0.8, so you do not run the battery flat. Then check that the supply can charge that battery in a reasonable time.
Example: 8 cameras × 0.5 A = 4 A at 12V. For 4 hours of backup: 4 A × 4 h ÷ 0.8 = 20 Ah, so a 12V 20 Ah battery or larger.
Access control and alarm panels need to know when they are running on battery. Choose a supply with alarm outputs: PSC-60 (AC OK and battery low), AD-55 (AC fail and battery low), SCP-50 (AC OK / AC fail) and DRS-240 (AC fail and battery low), and wire them to the panel inputs.
Add the current of all cameras at their voltage and divide by 0.8. Example: 8 cameras × 0.5 A = 4 A at 12V, so at least 5 A (60 W) plus the battery charging current if you want backup.
13.8V is the float voltage of a 12V sealed lead-acid battery. A 13.8V output keeps the backup battery charged while powering 12V cameras, which accept that voltage.
Roughly battery Ah × 0.8 ÷ load current. A 20 Ah battery with a 4 A load gives about 4 hours. Cold, battery age and camera IR at night reduce it.
PSC and AD are supplies with a built-in battery charger (UPS function). SCP is a 13.8V supply with an AC OK / AC fail signal. Check the battery charging current and alarm outputs in each datasheet.
Yes, if the panel has DIN rail and the voltage matches. The DRS-240-24 provides 24V with battery charging, DC UPS function and AC fail / battery low signals.
For monitored systems, yes: they tell the recorder or panel when mains is lost and when the battery is about to run out, so it can report and shut down cleanly.
Send the number of cameras, their current at 12V or 24V and the backup time you need to sales@htdelectronics.com, or request a quote.